Product name: 2018 new Lab2000 single station glove box
ETEX’s new Lab2000 glove box is a standard 1200 single-station glove box, which can be divided into one-piece and split-type. The vacuum glove box of this system is specially designed for the study of materials science, chemistry, semiconductor and related industries. Suitable for laser welding. Adopting German BASF deaeration material, American UOP high-efficiency water-absorbing material, the water and oxygen content in the glove box can continuously maintain a high-clean and high-purity gas environment with a gas purity below 1ppm for a long time, hand/automatic control system air pressure; hand/automatic control system The purification status of the gas purification system; automatic control of the reduction process of the gas purification system; automatic prompt and alarm function; system control parameter setting; system parameter recording; system actuator working condition monitoring; transparent front panel makes the operation more convenient and easy, and it is widely used in preparing nano Materials and battery electrode materials.
Box | ||
description | Material: stainless steel 1.4301 (SUS type 304), thickness 3 mm | |
Size: 1200mm(L) x 750mm(W) x 900mm(H) | ||
volume | 0.8 m³ | |
Front window | Panel: 8 mm thick safety tempered glass or 10 mm thick polycarbonate (optional) | |
Size: 1123mm(L) x 839mm(H) | ||
Glove mouth | Hard aluminum alloy material or polyoxymethylene material (optional) | |
220 mm diameter, O-ring seal | ||
gloves | Material: Butyl rubber | |
Thickness: 0.4 mm or 0.8mm (optional) | ||
filter | Outlet and inlet filters, filtration <0.3μm | |
illumination | LED lighting is located on the top of the front window | |
Leak rate | Leak detection is carried out in accordance with the oxygen method and pressure change method in ISO 10648-2: 1994 / EJ/T 1096-1999 "Sealed Chamber-Part 2: Tightness Classification and Related Inspection Methods". The final acceptance test is carried out in accordance with the standard of first-level tightness <0.05 vol%/h. | |
GP20 gas purification system | ||
description | Automatic removal of H2O and O2 | |
Single purification column system, automatic regeneration (optional GP200 double purification column) | ||
Closed gas circulation pipeline | ||
Use voltage | AC 230 V / 50-60 Hz, 10 A or AC 115 V / 50-60 Hz, 20 A (optional) | |
Working gas | Working gas: N2, Ar, He (purity ≥99.999%) | |
Regeneration gas: H2 accounts for 5%-10%, the rest is working gas (purity ≥99.999%) | ||
Vacuum pump | Specifications: Rotary vane vacuum pump, equipped with oil mist filter, with gas ballast control | |
Flow rate: 12 m³/h (7 cfm), double substrate, vacuum degree <2 x 10-3 mbar or dry pump (optional) | ||
Cyclic unit | Oil-free high-speed fan | |
Air volume: 80 m³/h | ||
valve | KF40 High Vacuum Valve | |
Leak rate | Leak detection is carried out in accordance with the oxygen method and pressure change method in ISO 10648-2: 1994 / EJ/T 1096-1999 "Sealed Chamber-Part 2: Tightness Classification and Related Inspection Methods". The final acceptance test is carried out according to the standard of level 1 tightness <0.05 vol%/h. | |
Control cabinet size | 600mm (L) x 800mm (D) x 870mm (H) | |
Transition cabin | ||
Large transition cabin | material | Stainless steel type 304 (1.4301), thickness 3 mm |
size | φ360mmx600mm(L) or φ390mmx600mm(L) (optional) | |
Vacuum | <1 x 10-2 mbar | |
Small transition cabin | material | Stainless steel type 304 (1.4301), thickness 2 mm |
size | φ150mm x 330mm(L) | |
Vacuum | <1 x 10-2 mbar | |
Cleaning system | ||
description | After setting the corresponding time and pressure, the system can automatically perform gas replacement on the box. | |
Analyzer | ||
Oxygen analyzer | size | 205 mm (L) x 80 mm (W) x 60 mm (H) |
Measuring range | 0-1000 ppm | |
Other oxygen analyzers | GE oxy.IQ™ Oxygen Transmitter | |
Moisture Analyzer | size | 205 mm (L) x 80 mm (W) x 60 mm (H) |
Measuring range | 0-500 ppm | |
Other water analyzers | GE VeriDri™ Dew-Point Transmitter | |
Solvent purification system | ||
description | Material: stainless steel 1.4301 (SUS type 304), thickness 3 mm | |
Internal size: 220mm(Φ) x 450mm(H) | ||
High quality activated carbon | ||
Optional equipment | ||
refrigerator | Independent control system, integrated in the side panel of the cabinet, temperature -35℃, volume 18L or 32L optional | |
Main body 304 stainless steel sheet, 5 layers of variable compartments | ||
R404 environmentally friendly refrigerant, imported with original packaging | ||
Heating chamber | Large transition configuration heating system, temperature is 200℃, temperature control is ±1℃ | |
other instructions | ||
certified product | ISO9001 certification, CE certification, UL certification | |
Warranty | One-year warranty, lifetime maintenance | |
Application note | For details, please refer to the dangerous, warning, and caution clauses in the manual | |
Packing size (W×D×H) | ||
weight |
Contact: Mr. Luo
Phone: 400-666-9912
Mobile: 136-9175-1230
Address: 4th Floor, Area C, Building 1, Aishang Technology Industrial Park, No. 108, Honghu Road, Songgang Street, Baoan District, Shenzhen, Guangdong Province